Home / Control and valves
Control and valves
The valve decides where the oil goes.
Valves send, limit, hold and share the oil flow. Pick a family below, or learn how the functions differ.
Identify this valve
Five valve families, one circuit.
- Read the markings on the body
- Locate it in the hydraulic diagram
- Photograph all faces and the ports
Valve families
Five valve families
Three groups. Directional valves choose the path. Function valves limit, hold or share. MRV and ARV are the relief valves of a valve block.
Directional
Directional control valves
Distributors for each movement of the machine. They send the pump flow to one side of the actuator and open the other side to tank.
Directional
Multi-section directional control valves
A stack of directional sections behind one inlet. Each section controls one movement.
FEK family
MRV valves
MRV stands for Main Relief Valve: the relief valve of the whole valve block, in its inlet section. It sets the highest pressure the block can reach.
FEK family
ARV valves
The relief valve of one section of a valve block, on its A or B work port. It protects that section, not the whole block.
Priority
Priority valves
Give one circuit, such as steering, the first call on the flow. The rest goes to the other circuits.
Directional
Directional valves: the distributor
A directional control valve connects four ports: P (pressure supply), T (tank), A and B (the two sides of the actuator). A 4/3 valve has four ports and three spool positions. A 4/2 valve has two positions and no centre. The spool can be moved by hand, by a solenoid, by pilot pressure or by a proportional control. On an excavator there is usually one section for each movement: boom, arm, bucket, swing, travel and attachments.
Function valves
Five functions that are easy to confuse
Relief
Limits system pressure by sending the excess flow to tank.
Pressure-reducing
Lowers the pressure in one branch compared with the rest of the circuit.
Check
Lets oil pass in one direction and blocks it in the other.
Throttle and flow control
Limits flow, and so sets the speed of the actuator.
Load-holding (counterbalance)
Holds the load in the cylinder and controls the lowering speed.
LS (load sensing) is a control signal to the pump regulator. It is not the main power line. Open-centre and closed-centre circuits are not interchangeable without analysis.
Pumps and valves
How a pump and a valve differ
Pump
Creates flow. Driven by the engine. Rated by displacement and speed. Does not set the pressure: the load does.
Valve
Decides what the flow does. Not driven. Directs it, limits its pressure, holds it or shares it. Never creates flow.
Safety
Before any work on a valve
Work on a hydraulic system only as the machine manufacturer instructs, and only after the pressure has been released safely. Valve settings come from the machine manufacturer’s documentation.