Valves · Priority valves
First call on the flow.
A priority valve gives one circuit first call on the available flow and passes what is left to the others.

Hydraulic Atlas
Anatomy of a priority valve
A load-sensing priority valve with the P, CF, EF and LS ports. Select a numbered marker or a part in the list.
Atlas · Pressure and priority valves
Load-sensing priority valve (P, CF, EF, LS)
A schematic section of a load-sensing priority valve. It gives the steering circuit first call on the flow through CF and passes the rest on through EF.
Schematic How this family is built
Swipe the drawing sideways to see all of it. The list below has the same descriptions.
Select a numbered marker on the drawing or a part in the list to see what it is, and what it does.
All 10 parts
-
Closes the spool bore at one end of the valve (the end opposite the spring in this drawing).
-
Orifices of this kind damp spool movement so the valve stays stable. The drawing shows its position schematically.
-
Divides the pump flow between CF and EF. Its position is set by the LS signal and the spring, so the flow to the steering unit follows the actual steering rate.
-
The body with the spool bore and the P, CF, EF and LS ports.
-
Biases the spool; together with the LS signal it sets the position and the flow split.
-
Closes the spring end of the bore and carries the LS orifice.
-
Receives the signal from the steering unit. It controls the distribution so that the flow to the steering unit follows the actual steering rate.
-
The remaining flow, available for the working hydraulics.
-
Pump flow enters here.
-
The flow needed for steering, led to the steering unit. A dedicated flow for the steering circuit, ahead of the other functions.
Data that identifies a priority or relief valve
Most of this is on the valve or in the machine documentation.
- machine make, model and year
- valve or block number, and the markings on the body or cartridge
- photos of every face with the markings visible
- which port is inlet, priority outlet and excess outlet
- the circuit that must have priority
Example
LS, CF and EF: a dedicated flow for steering
In a system with a priority valve and a load-sensing steering unit, steering has first priority. The oil flow the steering needs is led to the steering unit through the CF (controlled flow) port. The remaining flow is available for the working hydraulics through the EF (excess flow) port. The LS signal from the steering unit controls the split, so the flow to the steering follows the actual steering rate.
Other priority applications, such as a pilot supply, work on the same principle.
Do not confuse
Four functions that are easy to mix up
Main relief valve
Limits the pressure of the whole circuit by sending the excess flow to tank.
Relief on a work port
Protects one actuator port from pressure spikes, for example from the load pushing back. It opens at its own setting.
Make-up or anti-cavitation function
Lets oil in from the tank side when an actuator would otherwise draw a vacuum, so the chamber does not cavitate.
Priority flow
Gives one circuit first call on the flow and passes the rest on. It does not limit pressure.
What it does
One circuit first, the rest after
When one pump feeds several circuits, a priority valve supplies the priority circuit first, such as steering or a pilot supply. The remaining flow goes to the other circuits. The priority circuit keeps working even while the others are loaded.
Selection
Data needed to identify a priority valve
To read
- markings on the body or cartridge
- part number, if there is one
To measure or photograph
- all faces of the valve, with the markings visible
- ports: which is inlet, priority outlet and excess outlet, type and size
- the circuit that must have priority
- machine make, model and year
Send the markings, the port labels and the circuit that needs priority.