Skip to content

Home / Directional control valves

Control · Directional control valves

The distributor decides where the oil goes.

A directional control valve, also called a distributor, sends the pump flow to one side of an actuator and lets the oil from the other side return to tank.

Cutaway view of a red directional valve body with a spool, two solenoid ends and a row of ports.
Directional control valve · 3D cutaway

Hydraulic Atlas

Anatomy of a 4/3 directional valve

A section of a spring-centred valve with two solenoids, in neutral. Select a numbered marker or a part in the list. The ports are P (pressure), T (tank), A and B (work ports).

Atlas · Control valves

Solenoid-operated 4/3 directional valve

An original section of a spring-centred, double-solenoid 4/3 valve in its neutral position. The neutral position depends on the spool: this example blocks all four ports.

Schematic How this family is built

TTAPBsolenoid asolenoid b1. Solenoid (control)12. Centring springs23. Valve body34. Spool42. Centring springs21. Solenoid (control)15. Port A (work port)56. Port P (pressure inlet)67. Port B (work port)78. Port T (tank return)88. Port T (tank return)8

Swipe the drawing sideways to see all of it. The list below has the same descriptions.

  1. Pushes the spool through a push pin when energised. Coil voltage is on the coil label and is needed for identification. Solenoid “a” and “b” are named by the standard used, so confirm which end is which from the valve documentation.

  2. Spring-centred valves

    Return the spool to the centre when both solenoids are off. Other arrangements use a spring offset to one end, or a detent with no spring.

  3. The block with the spool bore and the ports on its mounting face. The mounting face is standardised (here ISO 4401 sizes 03 and 05).

  4. The moving element. Its lands close or open the connections between the ports. Spool types differ (for example 0, 2, 6, 7 and 8); each type has its own neutral and its own flow paths. The spool shown has four lands that close every port.

  5. One work port, connected to one side of the actuator.

  6. Supply from the pump.

  7. The other work port, connected to the other side of the actuator.

  8. Return to the tank. This valve has two tank chambers, one at each end, joined inside the body to a single T port on the mounting face.

Data that identifies a directional valve or valve block

Most of this is on the valve or in the machine documentation.

  • machine make, model and year
  • valve or block number from its plate or casting
  • photos of every face with the markings visible
  • number of sections and the function of each
  • control type and, for a solenoid, the coil voltage
  • port types and sizes

Neutral position

The neutral depends on the spool

The spool in the drawing has four lands that block all four ports in neutral. Other spools connect ports in neutral: all ports open together, or the work ports open to tank. The same valve body can take several spool types, each with its own neutral and flow paths. Open-centre and closed-centre circuits are not interchangeable without analysis. The machine’s hydraulic diagram shows which valve is fitted.

4/3 valve

Four ports, three positions

P is the supply, T is the tank, A and B go to the actuator. Move the spool and watch which ports connect. A 4/2 valve has two positions and no centre. Control can be manual, solenoid, pilot or proportional. The body can be a single monoblock or a stack of sections.

Spool position

Neutral position type

Neutral, closed centre: P, T, A and B are blocked. The actuator holds its position and the pump flow has to leave through a relief valve (omitted from the diagram).

PositionConnections
Position aP→A, B→T
Neutral (0) none (all blocked)
Position bP→B, A→T
  1. P Pressurised line (supply / working chamber)
  2. T Return line (to tank)
  3. A B Cylinder
Simplified symbol of a 4/3 spool valve. A 4/2 version has only positions a and b.

Where it is used

One valve section per movement

Excavators

A section for each function: boom, arm, bucket, swing, travel and attachments.

Loaders and backhoe loaders

Sections for lift, tilt and attachments, and for the backhoe functions.

Open or closed centre

The two circuits are not interchangeable without analysis.

Selection

Data needed to identify a distributor

To read

  • marking or part number on the body
  • number of sections and the function of each
  • control type: lever, solenoid (voltage on the coil label), pilot, proportional

To measure or photograph

  • port types and sizes, inlet and outlet
  • open-centre or closed-centre circuit
  • any built-in relief valve
  • machine make, model and year