Skip to content

Home / How hydraulics works

Flow Control Force

From oil flow to boom movement.

One circuit in one scene: tank, pump, 4/3 valve and cylinder. Pick a valve position and follow the oil.

Red FEK hydraulic pump with a regulator, seen from the side.

Flow Control Force

The circuit, step by step

The pump draws oil from the tank and supplies flow. The valve sends it into one chamber of the cylinder, while the oil from the other chamber returns to tank. Force comes from the pressure and the piston area.

  1. Tank stores the oil.
  2. Pump creates the flow.
  3. Valve chooses the direction.
  4. Cylinder turns flow and pressure into force and motion.
  5. Return sends the oil back to tank.

Valve position

Neutral (closed centre): P, T, A and B are blocked. The cylinder holds its position and the pump flow has to leave through the circuit relief valve (omitted from the diagram).

  1. 1 Tank
  2. 2 Pump
  3. 3 4/3 directional valve (P, T, A, B)
  4. 4 Cylinder
  • Pressurised line (supply / working chamber)
  • Return line (to tank)
  • Blocked / no flow
Closed-centre schematic without a relief valve or filtration.

Chapters

Each element, one page

Pump

Designs, regulators and nameplate data.

Valve

Spool positions and neutrals.

Cylinder

Chamber areas, F = p·A and v = Q/A.